Oct 30, 2024
Frontiers | Effects of cooling vest and personal protective equipment removal on thermoregulation in wildland firefighters during progressive thermal loads
Background: Wildland firefighters (WFFs) regularly face demanding physical and environmental conditions during their duties, such as high ambient temperatures, challenging terrains, heavy equipment
Background: Wildland firefighters (WFFs) regularly face demanding physical and environmental conditions during their duties, such as high ambient temperatures, challenging terrains, heavy equipment and protective gear. These conditions can strain thermoregulatory responses, leading to increased fatigue and posing risks to their health and safety. This study examined the effectiveness of two cooling interventions during physical activity in hot environments.
Methods: Eight active male WFFs participated, comparing the effects of wearing a cooling vest (VEST) and personal protective equipment removal (PASSIVE) against a control condition (PPE). Participants walked on a treadmill at a speed of 6 km·h−1 for approximately 75-min under hot conditions (30°C and 30% relative humidity). Incremental slope increases were introduced every 15 min after the initial 20 min of activity, with 5-min passive recovery between each increment. Physiological and perceptual parameters were monitored throughout the protocol.
Results: Significant main effects (p < 0.05) were observed in skin temperature (36.3 ± 0.2, 36.2 ± 0.4 and 35.4 ± 0.6°C in PPE, PASSIVE and VEST, respectively), physiological strain index (5.2 ± 0.4, 5.6 ± 1.1 and 4.3 ± 1.4 in PPE, PASSIVE and VEST) and thermal sensation (6.6 ± 0.6, 6.4 ± 0.7 and 5.3 ± 0.7 in PPE, PASSIVE, and VEST). However, no significant effects of the cooling strategies were observed on heart rate, gastrointestinal temperature or performance.
Conclusion: Despite the observed effects on physiological responses, neither cooling strategy effectively mitigated thermal strain in WFFs under the experimental conditions tested.
Wildland firefighting entails demanding physical activity over extended periods (1). These challenges are exacerbated by contextual factors such as high ambient temperatures, heavy manual tool handling, and steep terrain, all while wearing personal protective equipment (PPE) (2, 3). However, the cumulative effect of these factors can lead to a non-compensable heat load (3, 4), compromising physical performance and increasing the risk of heat-related disorders or even heatstroke (5, 6). To mitigate these risks, various cooling strategies have been explored, including personal cooling garments (7–9) and passive cooling techniques (10).
The scientific literature has extensively investigated the efficacy of personal cooling garments, such as water-perfused suits, air-perfused suits, ice vests, and phase change material vests, in mitigating heat strain and extending working durations in thermally demanding environments among various groups, including military personnel (11), military firefighters (12), and structural firefighters (8, 13). These garments have been shown to alleviate physiological and perceptual strain by facilitating heat transfer from the body’s core to the periphery, consequently attenuating the rise in central temperature (14). Given that a substantial body surface area is required for effective heat transfer, cooling garments typically focus on the torso, which constitutes approximately 24% of the total body surface area (15). Cooling vests, a subset of personal cooling garments, employ active cooling mechanisms to lower skin temperature through heat conduction (16). Extensively studied in sports contexts (17, 18), cooling vests have demonstrated their capacity to mitigate core temperature elevation and enhance performance when utilized before (pre-cooling) or during exercise (per-cooling), as well as expedite recovery post-exercise (post-cooling) (18). In occupational settings, employing an ice vest or a phase change material vest under firefighter gear (7, 19) and chemical, biological, radiological, and nuclear (CBRN) suits (8, 20) has been found to alleviate physiological and subjective strain during strenuous work in hot conditions, potentially extending tolerance times by 10–20%.
While PPE aims to shield first responders from diverse hazards, it can exacerbate metabolic and thermal responses, especially in hot environments (21, 22). Studies have showed that components such as helmets, gloves, and boots significantly impede body heat dissipation and heighten the thermophysiological strain on wildland firefighters (WFFs) (3) and structural firefighters (22). Consequently, removing one or more PPE components has been proposed as a heat mitigation strategy in occupational literature (10, 23). This passive approach enhances body heat dissipation by facilitating sweat evaporation and improving heat transfer through radiation and convection, thereby reducing body temperature and enhancing perceived comfort (24). Notably, this strategy has been observed to reduce thermal strain to levels comparable to active cooling during breaks in moderate environments (24°C) (10), making it a common choice among structural firefighters and WFFs (9, 25).
Despite the critical impact of heat strain on WFFs’ health and safety, there is a paucity of research investigating the effectiveness of cooling strategies, both active and passive, in mitigating the thermal load experienced by WFFs. This gap leaves unclear whether employing cooling strategies during wildland fire suppression task effectively mitigates the adverse effects of prolonged exposure to high temperatures. It is also crucial to note that while improving aerobic fitness and heat acclimatization have proven to be efficient strategies to combat heat stress over time (26, 27), they require long-term planning to realize benefits. Therefore, alternative measures or strategies may offer more immediate effectiveness. The aim of this study was to address this gap by examining the impact of both active (cooling vest) and passive cooling interventions (PPE removal) on WFFs’ physiological strain. We hypothesized that employing either a cooling vest or removing PPE would enhance heat dissipation in WFFs, leading to decreased core temperature and reduced cardiovascular strain, potentially increasing tolerance time.
Eight active and healthy male wildland firefighters (mean ± SD; age, 28.8 ± 3.2 years; height, 1.77 ± 0.06 m; body mass, 79.0 ± 17.7 kg; VO2max, 51.8 ± 7.8 mL·kg−1 min−1; body fat, 10.4 ± 3.6%; body surface area, 2.0 ± 0.2 m2), with more than 4 years of experience in wildland firefighting, participated voluntarily in this study. They engaged in physical activity 3–4 times per week (45–60 min per training session). None of the subjects reported using saunas or engaging in hot water bathing during the months preceding the study. Informed written consent was obtained from the volunteers before commencing the study. Prior to the commencement of the study, informed written consent was obtained from all volunteers. The study protocol adhered to the guidelines of the Helsinki Conference for research involving human subjects and was approved by the Ethics Committee of the University of León, Spain (025-2020, 22 July 2020).
Each participant completed four trials across four separate testing sessions in September, conducted at the end of the wildfire season. These trials were separated by at least 48 h (48–54 h), during which participants were instructed to avoid strenuous exercise, as well as abstain from consuming alcohol and caffeine within the preceding 24 h. During the initial session, participants’ height, nude body mass and body fat were measured before undertaking a graded exercise test to determine their maximal aerobic power. In the subsequent three trials, participants completed an extended graded heat tolerance test under three experimental conditions following a balanced randomized design: (i) wearing the PPE with no option to remove any part of the equipment or open the personal protective clothing during the test, serving as the control condition; (ii) wearing a cooling vest (Lightweight Body Cooling Vest, Artic Heat®, Miami, Australia) underneath the PPE and over the underwear to avoid skin irritation due to prolonged contact (28) (VEST); and (iii) removing the upper part of the protective clothing (i.e., fire-resistant overall), gloves, neck protection and helmet and remaining seated in the hot environmental conditions (i.e., 30°C and 30% relative humidity) during the 5-min recovery periods (PASSIVE).
The PPE utilized by Spanish WFFs (∼6 kg) includes personal protective clothing (65% fire-resistant viscose, 30% Nomex, and 5% Kevlar, surface mass 270 g·m−2, thermal resistance 0.019 m2 K·W−1, evaporative resistance 3.79 m2·Pa·W−1) and other elements such as helmet, neck protector, gloves, goggles, and mid-calf leather boots. Throughout the different experimental conditions, participants wore the same underwear clothing (i.e., cotton T-shirt, underpants, and socks) under the PPE. The cooling vest (1655.0 ± 485.7 g) was pre-cooled overnight in a freezer at −30°C and placed on each subject just before the trial commenced, positioned over the cotton T-shirt and under the PPE. During the three experimental condition trials, participants carried a backpack (20 kg) simulating the water backpack pump routinely used by Spanish WFFs during fire suppression (2). The total mass of the full ensemble was 27.6 ± 1.8, 26.9 ± 2.1, and 29.4 ± 2.3 kg for the PPE, PASSIVE, and VEST condition, respectively.
All tests were performed on a treadmill (h/p Cosmos Pulsar, h/p Cosmos sports and medical GMBH, Nussdorf-Traunstein, Germany). Prior to each tests, participants completed a 10-min warm-up at 60% of maximum heart rate (HR) (8–10 km·h−1) followed by 5-min of stretching. The first test conducted was the graded exercise test. During this test, participants wore sportswear (cotton T-shirt, shorts, and sneakers). The test started at a speed of 6 km·h−1 was raised by 1 km·h−1 every minute until volitional exhaustion. Throughout the entire test, the treadmill slope remained at 1%.
The extended graded heat tolerance tests were conducted at the same time of day (between 09:00 and 13:00 h) under controlled environmental conditions. The air temperature and relative humidity were maintained at 30°C and 30%, respectively, both during exercise and rest, simulating conditions observed during real wildland fire suppressions (2). The experimental protocol involved six bouts of walking at a speed of 6 km·h−1 with a gradual increase in slope (1, 2, 5, 8, 10, and 13%), interspersed with passive recovery periods of 5-min in between. The duration of each walking bout was 15-min, except for the first one, which lasted 20-min (Figure 1). This protocol, adapted from previous studies (3, 26), was designed to ensure that the selected speed and slope elicited an exercise intensity greater than 70% of maximum HR. This intensity simulates the moderate to high work intensities typically encountered in real wildland firefighting scenarios (2). During the recovery periods, participants were allowed to drink water ad-libitum at a controlled temperature of 15°C (29). The volume of water consumed at the end of each rest period was recorded.
Figure 1. Experimental study protocol overview.
Standard termination criteria were applied during each trial, which included: (i) core body temperature > 39.0°C; (ii) completion of 120-min of work, (iii) reaching 95% of participant’s maximum HR, or (iv) experiencing fatigue, nausea or self-termination (29).
During all experiments, heart rate (HR) response and respiratory gas exchange were continuously monitored using a 12-lead electrocardiogram and a breath-by-breath system, respectively (Medisoft Ergocard Professional, Medisoft Group, Sorinnes, Belgium). The maximum oxygen consumption (VO2max) was determined as the highest 30-s moving average. HR and VO2 data from the final 5 min of each exercise stage were considered as representative measurements for the extended graded heat tolerance test.
Body core temperature was recorded throughout the experimental trials using a gastrointestinal temperature pill (Tgi) (e-Celsius® Performance, Bodycap, Hérouville Saint-Clair, France), which participants activated and swallowed at least 8 h before commencing the test (30). Skin temperature (Tskin) was measured using four iButton sensors (DS1922L-F50, Maxim Integrated, Sunnyvale, California, United States), attached to the left major pectoral, medial left triceps, left anterior thigh and left calf with surgical tape (Fixomull, BSN Medical, Hamburg, Germany). The mean Tskin was calculated using the equation proposed by Ramanathan (31). Similarly, Tgi and Tskin were recorded every minute, with their values from the last 5 min of each exercise stage used for analysis.
The Physiological Strain Index (PSI) was calculated using Tgi and HR at baseline and every minute according to Tikuisis et al. (32). The PSI values were averaged over the final 5 min of each exercise stage for analysis. Capillary blood samples were collected from the earlobe after the completion of each exercise bout to measure blood lactate concentration (Lactate Scout, Senslab, Leipzig, Germany). During the final 30 s of each exercise stage, the Rating of Perceived Exertion (RPE) was assessed using the Borg scale (0–10) (33), administered consistently by the same researcher. Participants’ thermal sensation was recorded at the end of each exercise bout using a categorical scale (0–8) (34), with verbal anchors representing varying degrees of temperature sensation. Additionally, participants’ whole-body wet sensation was recorded at the end of each trial using a categorical scale (1–9) (35), with verbal anchors representing different levels of wetness.
At the beginning and end of each trial, participants, dressed only in underwear, and each clothing component was individually weighed (50 K150, COBOS, Hospitalet de Llobregat, Barcelona, Spain). This allowed for the calculation of total sweat production, sweat evaporation, and sweat residue in clothing and equipment (35, 36). Total sweat was adjusted for fluid intake. Finally, sweat efficiency was calculated as the ratio between sweat evaporation and total sweat (35, 36). Prior to the trial, urine specific gravity (USG) was measured with a refractometer (Atago URICON-NE, Atago, Tokyo, Japan) to confirm euhydration (USG ≤ 1.020). Participants ingested a bolus of water equivalent to 5 mL·kg−1 of body mass 30 min before the test to minimize the risk of dehydration (4).
Body heat storage was calculated as (ΔTb × Δt−1) × BM × AD−1 × cp, where cp represented the specific heat of body tissue (3,480 J·kg−1°C−1) and BM is the body mass in kg (37). Mean body temperature (Tb) in °C was estimated as Tb = 0.8·Tgi + 0.2·Tskin, as recommended for warm environments (37). The rate of change of Tb over the duration of the test (seconds) was calculated as ΔTb × Δt−1 in °C·s−1.
The results are presented as mean ± standard deviation (SD). Normality assumption was assessed using the Shapiro–Wilk’s test. The variables analyzed throughout trials were compared using a repeated measures two-way ANOVA with two within-subject factors (experimental condition and time). A one-way ANOVA with repeated measures was used to assess differences between body heat storage and sweat parameters. Bonferroni’s test was employed to determine significant differences between means when a significant F-value was obtained. Sphericity assumption was checked using Mauchly’s test; in cases of violation, the Greenhouse–Geisser adjustment was applied. For ordinal variables such as RPE, thermal and wet sensation, the Friedman test for repeated measures was employed to compare these variables across conditions and time. Post hoc analyses were conducted using the Wilcoxon signed-rank test with Bonferroni correction. Effect size was calculated using partial eta-squared (ηp2) for dependent variables, with values of 0.01, 0.06 and 0.14 interpreted as small, moderate and large effect sizes, respectively (38). Additionally, the magnitude of differences in pairwise analysis between experimental conditions was expressed as a standardized mean difference using Cohen’s d, with values of <0.20, 0.20–0.50, 0.51–0.80, and >0.80 categorized as trivial, small, moderate and large effects, respectively (39). Statistical significance was set at p < 0.05. All statistical analyses were performed using SPSS V.27.0 statistical software (SPSS, Inc., Chicago, IL, United States).
Tolerance time was similar across all conditions (74.1 ± 14.9, 75.0 ± 16.7, and 75.7 ± 18.7 min in PPE, PASSIVE, and VEST, respectively). However, only Tskin (F = 12.9, p < 0.01, ηp2 = 0.62), PSI (F = 6.0, p < 0.05, ηp2 = 0.50) RPE (χ2 = 9.3, p < 0.05, ηp2 = 0.47) and thermal sensation (χ2 = 12.3, p < 0.01, ηp2 = 0.60) were significantly affected by the study conditions. Lower (p < 0.05) Tskin, RPE, thermal and wet sensation were observed in the VEST condition (Table 1). Notably, significant differences (p < 0.05) in PSI were found only between the PASSIVE and VEST conditions. Furthermore, the thermophysiological response of the subjects varied with the test time (F = 26.9–325.3, χ2 = 77.4–101.3, p < 0.001, ηp2 = 0.61–0.96) (Figures 2–4). A significant interaction (p < 0.05) was observed between the study condition and test time in Tskin (F = 2.8, p < 0.05, ηp2 = 0.32) and PSI (F = 2.5, p < 0.05, ηp2 = 0.30).
Table 1. Physiological values (mean ± SD) recorded during the extended graded heat tolerance test under personal protective equipment (PPE), passive cooling (PASSIVE), and cooling vest (VEST) conditions.
Figure 2. Gastrointestinal and mean skin temperatures alongside physiological strain index across trials: personal protective equipment (PPE), passive cooling (PASSIVE) and cooling vest (VEST) conditions. Values are means ± SD. †, differences between PASSIVE and VEST (p < 0.05). *, differences between PPE and VEST (p < 0.05).
Figure 3. Comparison of oxygen consumption (VO2) and heart rate across trials under personal protective equipment (PPE), passive cooling (PASSIVE) and cooling vest (VEST) conditions. Values are means ± SD.
Figure 4. Perceived exertion, thermal sensation and humidity sensation across trials under personal protective equipment (PPE), passive cooling (PASSIVE) and cooling vest (VEST) conditions. Values are means ± SD. †, differences between PASSIVE and VEST (p < 0.05). *, differences between PPE and VEST (p < 0.05).
Finally, the body heat storage (58.4 ± 7.6, 52.7 ± 9.7, and 45.3 ± 15.0 W·m2), fluid intake (855.0 ± 345.5, 750.0 ± 523.8, and 738.7 ± 365.3 mL), total sweat loss (1922.7 ± 511.3, 1895.0 ± 578.5, and 1585.0 ± 502.4 gr), sweat rate (1,317 ± 363, 1,413 ± 457, and 1,229 ± 349 g·h−1) and evaporative efficiency (49.5 ± 4.7, 46.3 ± 13.1, and 46.5 ± 14.6%) were similar between PPE, PASSIVE, and VEST conditions.
The present study aimed to assess the impact of wearing a cooling vest or removing the top part of the PPE ensemble during intermittent rest periods on the thermal strain and tolerance time of WFFs. The primary finding of this investigation was that while the cooling vest led to reductions in mean Tskin, PSI, RPE and thermal sensation throughout most of the test, it did not have a significant effect on exercise tolerance time. However, neither cooling strategy proved effective in reducing the thermal or cardiovascular load or enhancing the tolerance time of WFFs under the experimental conditions tested.
Overall, the results from all three conditions revealed a substantial thermoregulatory and cardiovascular strain, as evidenced by final values of Tgi nearing 39°C (38.9 ± 0.4, 38.8 ± 0.3, and 38.6 ± 0.6°C in PPE, PASSIVE and VEST condition, respectively) and average HR values reaching 95% of maximal individual HR (93.8 ± 4.4, 96.9 ± 2.5, and 94.0 ± 4.8% in PPE, PASSIVE and VEST condition, respectively). These findings are consistent with previous laboratory-based studies investigating the physiological response of individuals wearing personal protective equipment (PPE) in hot conditions (3, 21, 22). The combination of environmental conditions and the high metabolic rate induced by the incremental protocol led to an uncompensable heat strain, irrespective of the cooling intervention, resulting in similar metabolic rates, cardiovascular loads (Table 1) and performance durations (~75 min).
The cooling vest did mitigate the increase in Tgi, particularly in the second half of the trial. However, this effect was insufficient to counter the high thermal load, as indicated by the similar rate of increase in Tgi across all conditions (0.025 ± 0.004, 0.023 ± 0.004 and 0.017 ± 0.008°C·min−1 in PPE, PASSIVE and VEST condition, respectively). Nevertheless, the lower PSI observed in the VEST condition suggests a beneficial impact of the cooling vest on overall physiological load. This effect may be attributed to the lower Tskin (Figure 2) in the VEST condition (PPE vs. VEST = 0.94°C, p < 0.05; PASSIVE vs. VEST = 0.79°C, p < 0.05) which may have resulted in reduced cutaneous blood flow and cardiovascular effort (40). However, the lack of significant effects of the cooling vest in our study is consistent with the findings of Teunissen et al. (7) and Carter et al. (41), who also examined the impact of cooling vests on structural firefighters’ heat strain during exercise (per-cooling). Specifically, this cooling intervention had no effect on core temperature or HR when firefighters performed steady-state exercise in controlled laboratory conditions (30°C and 50% relative humidity) (7), simulated an intervention in an underground tunnel wearing gas-tight suits, or engaged in a simulated rescue activity in either a hot (170°C) or neutral (15–20°C) environment (41).
While many studies in the literature have reported that cooling vests effectively decrease heat strain and increase tolerance time (8, 19, 20, 42), discrepancies in study protocols, particularly in terms of the net heat load imposed on participants, may explain the differing results. Moreover, the intensity of the cooling treatment might have been insufficient to adequately alleviate the uncompensable heat strain (23). Previous studies utilizing ice vests and phase change material vests with melting points above 10°C have also failed to demonstrate reductions in HR and core temperature (43, 44), indicating the necessity of substantial cooling power to impact core temperature. The effectiveness of cooling vests is largely influenced by factors such as mass, coverage area, and cooling medium (7, 19). Thus, the results obtained suggest that the cooling vest tested might not have had sufficient cooling power to adequately mitigate the thermal stress imposed by the experimental conditions.
During the breaks the passive recovery had a significant effect on Tskin, but not on Tgi or HR, being the cooling effect dissipated over subsequent exercise bouts. This observation may be attributed to the short duration of the breaks and the challenges associated with donning and doffing sweat-soaked PPE (45), which can impede the effectiveness of passive cooling during rest periods (4, 46, 47). Furthermore, the lack of an effect of the passive recovery might be linked to the fact that this strategy was implemented in the same hot environment as the treadmill walking bouts (30°C and 30% relative humidity), which might have limited its efficacy. In contrast to our findings, Hostler et al. (10) found that when performed during 20-min breaks in moderate environments (24°C), passive recovery strategy might reduce thermal strain to the level of active cooling in structural firefighters. These results suggest that for passive recovery to be effective, it should be conducted in thermoneutral environments and for a significantly longer duration than that applied in our study.
The significantly lower thermal sensation observed with the cooling vest compared to the other conditions may be linked to the lower mean Tskin achieved in the VEST condition. These findings support previous research indicating that thermal sensation is closely correlated with Tskin in warm environments (4, 7). However, it’s worth noting that a low thermal sensation without a concomitant reduction in Tgi, as observed in the VEST condition, might lead wildland firefighters to perceive a false sense of comfort, potentially exacerbating heat strain and the risk of heat-related illnesses if work continues (4).
No differences were found in total sweat loss or evaporative efficiency between conditions. However, the volume of sweat produced was lower in the VEST condition compared to PPE (~18%) and PASSIVE (~16%). This reduction in sweat loss might be attributed to the visibly lower Tskin in the VEST condition (7, 11). Alternatively, the cooling vest might hinder sweat evaporation from the body (43) and fail to contribute positively to the heat balance, as evidenced by the approximately 3% lower evaporative efficiency in the VEST condition compared to the PPE condition. However, the lack of statistically significant differences in total sweat produced and evaporative efficiency across conditions suggest that evaporation may have been equally restricted across conditions by the WFFs’ PPE (7).
The present study had several potential limitations. One of these was the small sample size, which might restrict the study’s conclusions and limit the ability to observe the effectiveness of the cooling strategies examined. Future studies should consider the expected variability in measures of thermoregulation and include a larger sample size (~20 subjects) to improve the robustness of the assessment of the cooling strategies. Additionally, all participants were male WFFs, meaning the results cannot be extrapolated to female WFFs. The different anthropometric characteristics and thermophysiological response of females compared to males (48) could condition the impact of the examined strategies. Another limitation was the hydration protocol used. Participants were allowed to drink water ad-libitum during rest periods, which could have been a confounding variable in this study. However, we believe this did not substantially affect the results, as there were no significant differences in the amount of liquid consumed by WFFs under the different conditions. Furthermore, this strategy may be appropriate for ensuring optimal fluid replacement (49). Lastly, the use of the cooling vest resulted in an approximate 2 kg increase in weight compared to the other conditions, which could have increased the workload for the subjects, particularly in the final minutes of the test (~2%) and raised the metabolic cost of walking in the VEST condition, potentially limiting the effectiveness of this strategy. However, since this weight was distributed around the torso, its impact on the metabolic rate was small (50).
In summary, despite the main effects observed in Tskin, PSI, RPE and thermal sensation due to the study conditions, as well as the interaction effect between conditions and test time on Tskin and PSI, these did not translate into an increase in tolerance time or a reduction in core temperature and cardiovascular effort among WFFs. While these findings suggest a more pronounced effect of using cooling vests on WFFs’ responses, the high metabolic rate of the protocol or the duration and environmental conditions during recovery periods might have influenced the results obtained. Therefore, future studies should investigate whether passive cooling strategies, coordinated with appropriate work:recovery protocols, could prove effective. Additionally, although practical limitations may exist regarding the use of cooling vests, further research should explore their potential as per-cooling measures or as a post-fire intervention recovery strategy for WFFs facing high thermal loads.
The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.
The studies involving humans were approved by Ethics Committee of the University of León. The studies were conducted in accordance with the local legislation and institutional requirements. The participants provided their written informed consent to participate in this study.
JG-A: Conceptualization, Data curation, Investigation, Methodology, Writing – original draft. JAR-M: Formal analysis, Funding acquisition, Methodology, Writing – review & editing. FG-H: Data curation, Writing – original draft. JR-M: Data curation, Investigation, Visualization, Writing – original draft. PC: Methodology, Writing – review & editing. JV-C: Conceptualization, Funding acquisition, Methodology, Writing – review & editing. BC-L: Conceptualization, Formal analysis, Methodology, Writing – review & editing.
The author(s) declare that financial support was received for the research, authorship, and/or publication of this article. This research was supported by a grant for research projects in occupational risk prevention from the Consejería de Industria, Comercio y Empleo, Junta de Castilla y León (Spain) (INVESTUN/22/LE/0001). The authors wish to thank the European Social Fund, the Operative Program of Castilla y León and Junta de Castilla y León through the Regional Ministry of Education for supporting the predoctoral grants.
The authors wish to thank all the wildland firefighters who participated in this study for their commitment and dedication.
The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.
1. Sol, JA, Ruby, BC, Gaskill, SE, Dumke, CL, and Domitrovich, JW. Metabolic demand of hiking in wildland firefighting. Wilderness Environ Med. (2018) 29:304–14. doi: 10.1016/j.wem.2018.03.006
Crossref Full Text | Google Scholar
2. Rodríguez-Marroyo, JA, López-Satue, J, Pernía, R, Carballo, B, García-López, J, Foster, C, et al. Physiological work demands of Spanish wildland firefighters during wildfire suppression. Int Arch Occup Environ Health. (2012) 85:221–8. doi: 10.1007/s00420-011-0661-4
Crossref Full Text | Google Scholar
3. Carballo-Leyenda, B, Villa, JG, López-Satué, J, Collado, PS, and Rodríguez-Marroyo, JA. Fractional contribution of wildland firefighters’ personal protective equipment on physiological strain. Front Physiol. (2018) 9:1–10. doi: 10.3389/fphys.2018.01139
Crossref Full Text | Google Scholar
4. Barr, D, Reilly, T, and Gregson, W. The impact of different cooling modalities on the physiological responses in firefighters during strenuous work performed in high environmental temperatures. Eur J Appl Physiol. (2011) 111:959–67. doi: 10.1007/s00421-010-1714-1
Crossref Full Text | Google Scholar
5. Cheung, SS, Mclellan, TM, and Tenaglia, S. The thermophysiology of uncompensable heat stress physiological manipulations and individual characteristics. Sport Med. (2000) 29:329–59. doi: 10.2165/00007256-200029050-00004
Crossref Full Text | Google Scholar
6. Cuddy, JS, and Ruby, BC. High work output combined with high ambient temperatures caused heat exhaustion in a wildland firefighter despite high fluid intake. Wilderness Environ Med. (2011) 22:122–5. doi: 10.1016/j.wem.2011.01.008
Crossref Full Text | Google Scholar
7. Teunissen, LPJ, Wang, L-C, Chou, S-N, Huang, C, Jou, G-T, and Daanen, HAM. Evaluation of two cooling systems under a firefighter coverall. Appl Ergon. (2014) 45:1433–8. doi: 10.1016/j.apergo.2014.04.008
Crossref Full Text | Google Scholar
8. Maley, MJ, Minett, GM, Bach, AJE, Stewart, KL, and Stewart, IB. Extending work tolerance time in the heat in protective ensembles with pre- and per-cooling methods. Appl Ergon. (2020) 85:103064. doi: 10.1016/j.apergo.2020.103064
Crossref Full Text | Google Scholar
9. Fullagar, H, Notley, SR, Fransen, J, Richardson, A, Stadnyk, A, Lu, D, et al. Cooling strategies for firefighters: Effects on physiological, physical, and visuo-motor outcomes following fire-fighting tasks in the heat. J Therm Biol. (2022) 106:103236. doi: 10.1016/j.jtherbio.2022.103236
Crossref Full Text | Google Scholar
10. Hostler, D, Reis, SE, Bednez, JC, Kerin, S, and Suyama, J. Comparison of active cooling devices with passive cooling for rehabilitation of firefighters performing exercise in thermal protective clothing: A report from the fireground rehab evaluation (FIRE) trial. Prehospital Emerg Care. (2010) 14:300–9. doi: 10.3109/10903121003770654
Crossref Full Text | Google Scholar
11. Constable, SH, Bishop, PA, Nunneley, SA, and Chen, T. Intermittent microclimate cooling during rest increases work capacity and reduces heat stress. Ergonomics. (1994) 37:277–85. doi: 10.1080/00140139408963645
Crossref Full Text | Google Scholar
12. Hagan, RD, Huey, KA, and Bennett, BL. Cool vests work under firefighting ensemble. Def Tech Inf Cent. (1994)
Google Scholar
13. Kim, J, Coca, A, Williams, WJ, and Roberge, RJ. Effects of liquid cooling garments on recovery and performance time in individuals performing strenuous work wearing a firefighter ensemble. J Occup Environ Hyg. (2011) 8:409–16. doi: 10.1080/15459624.2011.584840
Crossref Full Text | Google Scholar
14. Kay, D, Taaffe, DR, and Marino, FE. Whole-body pre-cooling and heat storage during self-paced cycling performance in warm humid conditions. J Sports Sci. (1999) 17:937–44. doi: 10.1080/026404199365326
Crossref Full Text | Google Scholar
15. Tikuisis, P, Meunier, P, and Jubenville, CE. Human body surface area: Measurement and prediction using three dimensional body scans. Eur J Appl Physiol. (2001) 85:264–71. doi: 10.1007/s004210100484
Crossref Full Text | Google Scholar
16. Périard, JD, Eijsvogels, TMH, and Daanen, HAM. Exercise under heat stress: thermoregulation, hydration, performance implications, and mitigation strategies. Physiol Rev. (2021) 101:1873–979. doi: 10.1152/physrev.00038.2020
Crossref Full Text | Google Scholar
17. Bongers, CCWG, Thijssen, DHJ, Veltmeijer, MTW, Hopman, MTE, and Eijsvogels, TMH. Precooling and percooling (cooling during exercise) both improve performance in the heat: A meta-analytical review. Br J Sports Med. (2015) 49:377–84. doi: 10.1136/bjsports-2013-092928
Crossref Full Text | Google Scholar
18. Bongers, CCWG, Hopman, MTE, and Eijsvogels, TMH. Cooling interventions for athletes: An overview of effectiveness, physiological mechanisms, and practical considerations. Temperature. (2017) 4:60–78. doi: 10.1080/23328940.2016.1277003
Crossref Full Text | Google Scholar
19. Bennett, BL, Hagan, RD, Huey, KA, Minson, C, and Cain, D. Comparison of two cool vests on heat-strain reduction while wearing a firefighting ensemble. Eur J Appl Physiol Occup Physiol. (1995) 70:322–8. doi: 10.1007/BF00865029
PubMed Abstract | Crossref Full Text | Google Scholar
20. Kenny, GP, Schissler, AR, Stapleton, J, Piamonte, M, Binder, K, Lynn, A, et al. Ice cooling vest on tolerance for exercise under uncompensable heat stress. J Occup Environ Hyg. (2011) 8:484–91. doi: 10.1080/15459624.2011.596043
Crossref Full Text | Google Scholar
21. Selkirk, GA, and McLellan, TM. Physical work limits for toronto firefighters in warm environments. J Occup Environ Hyg. (2004) 1:199–212. doi: 10.1080/15459620490432114
Crossref Full Text | Google Scholar
22. Lee, JY, Kim, S, Jang, YJ, Baek, YJ, and Park, J. Component contribution of personal protective equipment to the alleviation of physiological strain in firefighters during work and recovery. Ergonomics. (2014) 57:1068–77. doi: 10.1080/00140139.2014.907449
Crossref Full Text | Google Scholar
23. McEntire, SJ, Suyama, J, and Hostler, D. Mitigation and prevention of exertional heat stress in firefighters: a review of cooling strategies for structural firefighting and hazardous materials responders. Prehospital Emerg Care. (2013) 17:241–60. doi: 10.3109/10903127.2012.749965
Crossref Full Text | Google Scholar
24. McLellan, TM, Daanen, HAM, and Cheung, SS. Encapsulated environment. Compr Physiol. (2013) 3:1363–91. doi: 10.1002/cphy.c130002
Crossref Full Text | Google Scholar
25. Carballo-Leyenda, B, Villa-Vicente, JG, Delogu, GM, Rodríguez-Marroyo, JA, and Molina-Terrén, DM. Perceptions of heat stress, heat strain and mitigation practices in wildfire suppression across Southern Europe and Latin America. Int J Environ Res Public Health. (2022) 19:12288. doi: 10.3390/ijerph191912288
Crossref Full Text | Google Scholar
26. Alhadad, SB, Tan, PMS, and Lee, JKW. Efficacy of heat mitigation strategies on core temperature and endurance exercise: a meta-analysis. Front Physiol. (2019) 10:71. doi: 10.3389/fphys.2019.00071
Crossref Full Text | Google Scholar
27. Lui, B, Cuddy, JS, Hailes, WS, and Ruby, BC. Seasonal heat acclimatization in wildland firefighters. J Therm Biol. (2014) 45:134–40. doi: 10.1016/j.jtherbio.2014.08.009
Crossref Full Text | Google Scholar
28. Zare, M, Dehghan, H, Yazdanirad, S, and Khoshakhlagh, AH. Comparison of the impact of an optimized ice cooling vest and a paraffin cooling vest on physiological and perceptual strain. Safety Health Work. (2019) 10:219–23. doi: 10.1016/j.shaw.2019.01.004
Crossref Full Text | Google Scholar
29. Selkirk, GA, McLellan, TM, and Wong, J. Active versus passive cooling during work in warm environments while wearing firefighting protective clothing. J Occup Environ Hyg. (2004) 1:521–31. doi: 10.1080/15459620490475216
Crossref Full Text | Google Scholar
30. Larsen, B, Snow, R, Williams-Bell, M, and Aisbett, B. Simulated firefighting task performance and physiology under very hot conditions. Front Physiol. (2015) 6:1–9. doi: 10.3389/fphys.2015.00322
Crossref Full Text | Google Scholar
31. Ramanathan, NL. A new weighting system for mean surface temperature of the human body. J Appl Physiol. (1964) 19:531–3. doi: 10.1152/jappl.1964.19.3.531
Crossref Full Text | Google Scholar
32. Tikuisis, P, McLellan, TM, and Selkirk, G. Perceptual versus physiological heat strain during exercise-heat stress. Med Sci Sports Exerc. (2002) 34:1454–61. doi: 10.1097/00005768-200209000-00009
Crossref Full Text | Google Scholar
33. Borg, GA. Psychophysical bases of perceived exertion. Med Sci Sports Exerc. (1982) 14:377–81.
Google Scholar
34. Young, AJ, Sawka, MN, Epstein, Y, Decristofano, B, and Pandolf, KB. Cooling different body surfaces during upper and lower body exercise. J Appl Physiol. (1987) 63:1218–23. doi: 10.1152/jappl.1987.63.3.1218
Crossref Full Text | Google Scholar
35. Havenith, G, and Heus, R. A test battery related to ergonomics of protective clothing. Appl Ergon. (2004) 35:3–20. doi: 10.1016/j.apergo.2003.11.001
Crossref Full Text | Google Scholar
36. Kofler, P, Burtscher, M, Heinrich, D, Bottoni, G, Caven, B, Bechtold, T, et al. Performance limitation and the role of core temperature when wearing light-weight workwear under moderate thermal conditions. J Therm Biol. (2015) 47:83–90. doi: 10.1016/j.jtherbio.2014.11.007
Crossref Full Text | Google Scholar
37. Bröde, P, Havenith, G, Wang, X, Candas, V, den Hartog, EA, Griefahn, B, et al. Non-evaporative effects of a wet mid layer on heat transfer through protective clothing. Eur J Appl Physiol. (2008) 104:341–9. doi: 10.1007/s00421-007-0629-y
Crossref Full Text | Google Scholar
38. Lakens, D. Calculating and reporting effect sizes to facilitate cumulative science: a practical primer for t-tests and ANOVAs. Front Psychol. (2013) 4:863. doi: 10.3389/fpsyg.2013.00863
Crossref Full Text | Google Scholar
39. Cohen, J. Statistical power analysis for the behavioral sciences. 2nd ed. New Jersey, NJ: Lawrence Erlbaum (1988).
Google Scholar
40. Bogerd, N, Perret, C, Bogerd, CP, Rossi, RM, and Daanen, HAM. The effect of pre-cooling intensity on cooling efficiency and exercise performance. J Sports Sci. (2010) 28:771–9. doi: 10.1080/02640411003716942
Crossref Full Text | Google Scholar
41. Carter, JMÃ, Rayson, MP, Wilkinson, DM, Richmond, V, and Blacker, S. Strategies to combat heat strain during and after firefighting. J Thermal Biol. (2007) 32:109–16. doi: 10.1016/j.jtherbio.2006.12.001
Crossref Full Text | Google Scholar
42. Chou, C, Tochihara, Y, and Kim, T. Physiological and subjective responses to cooling devices on firefighting protective clothing. Eur J Appl Physiol. (2008) 104:369–74. doi: 10.1007/s00421-007-0665-7
Crossref Full Text | Google Scholar
43. Gao, C, Kuklane, K, and Holmér, I. Cooling vests with phase change materials: the effects of melting temperature on heat strain alleviation in an extremely hot environment. Eur J Appl Physiol. (2011) 111:1207–16. doi: 10.1007/s00421-010-1748-4
Crossref Full Text | Google Scholar
44. House, JR, Lunt, HC, Taylor, R, Milligan, G, Lyons, JA, and House, CM. The impact of a phase-change cooling vest on heat strain and the effect of different cooling pack melting temperatures. Eur J Appl Physiol. (2013) 113:1223–31. doi: 10.1007/s00421-012-2534-2
Crossref Full Text | Google Scholar
45. Boorady, LM, Barker, J, Lee, YA, Lin, SH, Cho, E, and Ashdown, SP. Exploration of firefighter bunker gear part 2: Assessing the needs of the female firefighter. J Text Apparel Technol Manag. (2013) 8:5.
Google Scholar
46. Kim, S, Kim, DH, Lee, HH, and Lee, JY. Frequency of firefighters’ heat-related illness and its association with removing personal protective equipment and working hours. Ind Health. (2019) 57:370–80. doi: 10.2486/indhealth.2018-0063
Crossref Full Text | Google Scholar
47. Walker, A, Argus, C, Driller, M, and Rattray, B. Repeat work bouts increase thermal strain for Australian firefighters working in the heat. Int J Occup Environ Health. (2015) 21:285–93. doi: 10.1179/2049396715Y.0000000006
Crossref Full Text | Google Scholar
48. Yanovich, R, Ketko, I, and Charkoudian, N. Sex differences in human thermoregulation: relevance for 2020 and beyond. Physiology. (2020) 35:177–84. doi: 10.1152/physiol.00035.2019
Crossref Full Text | Google Scholar
49. Suppiah, HT, Ng, EL, Wee, J, Taim, BC, Huynh, M, Gastin, PB, et al. Hydration status and fluid replacement strategies of high-performance adolescent athletes: an application of machine learning to distinguish hydration characteristics. Nutrients. (2021) 13:4073. doi: 10.3390/nu13114073
Crossref Full Text | Google Scholar
50. Dorman, LE, and Havenith, G. The effects of protective clothing on energy consumption during different activities. Eur J Appl Physiol. (2009) 105:463–70. doi: 10.1007/s00421-008-0924-2
Crossref Full Text | Google Scholar
Keywords: active cooling, passive cooling, thermoregulation, heat strain mitigation, personal protective equipment
Citation: Gutiérrez-Arroyo J, Rodríguez-Marroyo JA, García-Heras F, Rodríguez-Medina J, Collado PS, Villa-Vicente JG and Carballo-Leyenda B (2024) Effects of cooling vest and personal protective equipment removal on thermoregulation in wildland firefighters during progressive thermal loads. Front. Public Health. 12:1408591. doi: 10.3389/fpubh.2024.1408591
Received: 28 March 2024; Accepted: 30 July 2024; Published: 07 August 2024.
Edited by:
Reviewed by:
Copyright © 2024 Gutiérrez-Arroyo, Rodríguez-Marroyo, García-Heras, Rodríguez-Medina, Collado, Villa-Vicente and Carballo-Leyenda. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
*Correspondence: Jose A. Rodríguez-Marroyo, [email protected]
Disclaimer: All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.